nmemmertandClaude Sonnet 4.6 dd85a79d55 Fix false-positive slow alerts: require 3 consecutive checks + use P95 baseline
Previously a single check above 2× average response time fired an alert.
This caused false positives from normal network variance.

- scheduler.js: track consecutive slow checks per resource; only alert after
  3 in a row (resets to 0 when response time normalises)
- monitorService.js: calculateResponseTimeBaseline now returns P95 instead
  of mean, making 2× baseline a much more realistic slow threshold